FU1 (5 A slow-blow) blows instantly at power-on.
Coil fuse FU1 blows the moment the game is switched on
Cause: The coil bridge rectifier BR1 (35 A 200 V) has shorted; less often the varistor VA1 shorted, usually from high line voltage.
Checks
- Test BR1 with the meter on diode setting.
- Check VA1 for a short.
- Check R1 (600 ohm 10 W): it should be within 10% and not open.
Fix
- Replace BR1 or VA1 as found, then fit a new 5 A slow-blow FU1.
Unplug the game before pulling fuses or working on the power supply; the transformer side carries line voltage.