Shortly after power-up, the wiring to a chain of three lamps on the upper playfield heats up, smokes and starts to melt, even with the bulbs removed. No fuse blows.
Wires to a few upper playfield lamps get hot and melt: bent lamp socket tab
Cause: A bent tab on one of the lamp sockets in that chain was shorting.
Checks
- Switch off at once and unplug the lamp connector at the power board until the fault is found.
- Inspect every socket in the hot chain, especially any that flickered before, for a tab bent against the bracket or another lug.
- Check the fuse rating on that lamp supply: wires should not be able to melt without a fuse blowing.
Fix
- Straighten or replace the faulty socket and replace any heat-damaged wire.
Overheating wiring is a fire risk; do not leave the game on while this fault is present.