After storage the game blows the 5 A slow-blow line fuse in the metal power switch box under the cabinet as soon as it is turned on.
Main fuse in the power switch box blows at switch-on: shorted varistor
Cause: The surge-protection varistor wired across the incoming line inside the power switch box had failed shorted (they die from power surges). Battery leakage on the CPU board does not blow this fuse.
Checks
- Confirm the fuse is the correct value and type.
- With the game unplugged, open the power switch box and look at the varistor (a disc-shaped part across the line) and the line filter for cracks or scorching.
- To prove it, the varistor can be disconnected temporarily: if the fuse then holds, it is the culprit. Do not leave the game running unattended without one.
Fix
- Replace the varistor, and the line filter if it is damaged, then fit a new fuse of the correct rating.
The power switch box carries mains line voltage. Unplug the game from the wall before opening it; switching it off is not enough.
Systems
Games
Related tips
- Main cabinet fuse blows instantly after a power surge: shorted varistor
- Shorted or open bridge rectifiers
- Game dead after a lightning strike or surge
- Row 1 short error and F114 blows at once: fault in the 18 V lamp supply
- Driver board LED1 off: switch matrix 12 V missing (WPC-S and earlier)
Source: Pinball Repair help group!! (Facebook group)