Checklist for a dead small or medium dot matrix display
Steps
- Measure -110, -98, +68, +12 and +5 V at the display board (within 10 percent).
- Check the +5 V connection to the display board again.
- Check the backbox 18 V lamp matrix fuse.
- Check the data ribbon cable from the CPU board to the display.
- On a 128 x 16 display, check or replace R95.
- Replace the display ROMs.
The display power supply carries about 100 V or more; work on it with the game unplugged and let the capacitors discharge.