Each switch works alone, but closing several switches in the same row or other columns gives false readings.
False switch readings only when several switches are closed
Cause: A switch diode has shorted. (An open diode, by contrast, only stops its own switch working.)
Checks
- Diode-test the switches involved.
Fix
- Replace the shorted diode.