The servo is good but the blinders still do not respond.
Tommy: blinder servo board never activates
Cause: The servo board never sees its clear signal go high. The board is fed from CPU connector CN3: P2 pin 1 +12 V, pin 3 clock, pin 4 data, pin 5 clear, pin 6 +5 V, pin 7 ground.
Checks
- Probe clock and data at P2 with a logic probe.
- Measure clear at P2 pin 5: it must reach 5 V.
Fix
- If clear never goes high, tie pin 1 of the 74LS174 at U4 to P2 pin 6 (+5 V) so the board stays enabled.