Testing the DIP switch inputs with the test EPROM
Steps
- During the I/O test watch U4 port B, which echoes the inputs. Port A inputs come through buffers Z13 and Z14.
- Set all 32 DIP switches off: PB0-PB7 should stay still at 0 V. A pulsing line points at a bad gate in Z13 or Z14 (often blown by playfield matrix shorts).
- Turn DIP 1 on: PB7 should start pulsing. DIP 2 drives PB6, DIP 3 PB5 and so on.
- DIPs 9 to 32 should have no effect here; if one does, check bank select chips Z33 (74154) and Z15 (7432).
- If an output ignores its switch, check the DIP switch itself (often worn or corroded), output buffers Z11 and Z12, input buffers Z13/Z14, Z15/Z33 and finally the RIOT.
- Z11 can be pulled to see if it is jamming a line; Z12 cannot, as later boards also use it as an address buffer. A chip that is too hot to touch is a likely culprit.