Adjust a Gold Mech acceptor for a US quarter
Steps
- Set the acceptor upright and level.
- Loosen the hex lock screw on the magnet holder and back out the slotted hex screw.
- With a real US 25 cent piece in the entry, wind the diameter adjuster clockwise until the coin drops into the cradle, the cradle tips, and the coin leans on the magnet.
- Now wind the slotted screw in until the coin only just passes the magnet, then give it half a turn more.
- Tighten the lock nut.
Systems
Related tips
Source: Premier Technology Parts Catalog (System 80, 80A and 80B), Gottlieb / Premier