Clean a Gold Mech coin acceptor
Steps
- Take out the acceptor: undo its two screws, swing the back of the body away from the lockout side and lift it out.
- Swing the gate open and draw a screwdriver tip along the magnet edges so the steel filings stick to it.
- Wash the acceptor in water with a small brush, rinse it with very hot water and blow it dry with compressed air.
- Do not oil it: the magnet test needs coins to roll at a steady speed, and oil or grime slows them.
- If coins still reject, look for worn, bent or broken parts and replace them.
Take care with boiling water.
Systems
Related tips
Source: Premier Technology Parts Catalog (System 80, 80A and 80B), Gottlieb / Premier