pintech.app

Clean a Gold Mech coin acceptor

Steps

  • Take out the acceptor: undo its two screws, swing the back of the body away from the lockout side and lift it out.
  • Swing the gate open and draw a screwdriver tip along the magnet edges so the steel filings stick to it.
  • Wash the acceptor in water with a small brush, rinse it with very hot water and blow it dry with compressed air.
  • Do not oil it: the magnet test needs coins to roll at a steady speed, and oil or grime slows them.
  • If coins still reject, look for worn, bent or broken parts and replace them.

Take care with boiling water.

Systems

Related tips

Source: Premier Technology Parts Catalog (System 80, 80A and 80B), Gottlieb / Premier