Switches stop working after a probe slipped, a coil was mis-wired, or a switch wire touched coil or GI power.
Switch matrix dead after coil or GI voltage touched it
Cause: 24 V DC coil or 6.3 V AC GI on a switch line has damaged Z8 (7404 strobes), Z9 (7405 returns 0-5) or Z28 (7405 returns 6-7), and possibly the U5 spider.
Checks
- Run the Z8/Z9/Z28 logic probe checks.
Fix
- Replace the 7404/7405 chips. If U5 is damaged the board cannot be repaired and must be replaced.