Checking the +60 V filter caps on a display board
Steps
- Power off and unplug the display.
- Put the red (positive) lead on the capacitor negative and black on positive: about 25K to 30K ohms.
- Reverse the leads: open.
- Compare with a good display if readings look odd.
Systems
Related tips
- The display voltages to check
- How the Gottlieb fluorescent displays work
- Measuring voltages on a display board
- Meter check of the display board 7432
- How the System 80 fluorescent displays light
- Meter checks on a display tube
- Meter check of the UDN6118 display drivers
- Use the shared wiring to locate display faults
Source: Troubleshooting Gottlieb Displays (On Target technical newsletter, vol. 3 issue 7, 1982), Gottlieb "On Target"