One switch column fails the clip-lead or logic-probe test.
Fixing a dead switch column on the CPU board
Cause: Usually the column's 2N3904 (Q42-Q49). Less often the 1.5k resistor (R71-R78), the 4.7k network SR15, the 74LS244 at U40 or the PIA at U38.
Checks
- Test the column transistor.
- Check the 1.5k resistor for that column.
- Measure SR15 pin 1 to each of pins 2-10: about 4.7k each.
- Column paths: 1J8-1 Q45/R77/SR15-2; 1J8-2 Q49/R78/SR15-3; 1J8-3 Q44/R75/SR15-4; 1J8-4 Q48/R76/SR15-5; 1J8-5 Q43/R73/SR15-7; 1J8-7 Q47/R74/SR15-8; 1J8-8 Q42/R71/SR15-9; 1J8-9 Q46/R72/SR15-10.
Fix
- Replace the bad transistor, resistor or network.
- If those test good, replace U40 (74LS244), then the 6821 at U38 last, or prove the PIA with a test EPROM first.