"Factory Setting" or "Adjustment Error" persists with fresh batteries and a good holder.
Settings lost although the batteries are good (blocking diode D2)
Cause: Blocking diode D2 (1N4148 or 1N914) beside the battery holder is open or shorted, or U25 is bad.
Checks
- Game off, black lead on the backbox ground strap: both sides of D2 should read about 4.2 to 4.8 V, the banded (U25) side about 0.3 to 0.5 V lower.
- Voltage on only the battery side means D2 is open; equal voltage on both sides means it is shorted.
- Check U25 pin 24 (ground is pin 20): about 4.3 V with the game off.
- Diode test: 0.4 to 0.6 one way, no reading the other.
Fix
- Replace D2.
- If all voltages are right, suspect U25 or light corrosion in the holder limiting current.