pintech.app

Zero audits, restore factory settings or auto-cycle with the DIP switches

Steps

  • With the game in attract mode, set the coin door switch to Manual-down.
  • Press Advance and keep the coin door open.
  • Set upper-bank DIP switches 8, 7 and 6 all to off.
  • Turn on just one: switch 8 zeroes the audit totals, switch 7 restores factory settings, switch 6 starts auto-cycle diagnostics.
  • Press the Master Command button on the CPU board (the upper button, above the diagnostic button). The CPU LEDs light while it is held.
  • Turn the game off and on twice to get back to attract mode.
  • Removing the AA batteries for about 10 seconds also clears audits and settings.

Systems

Related tips

Source: Repairing Williams System 3 to System 7 Pinball 1977 to 1984, Part Two, Clay Harrell (pinrepair.com)