One GI string on the playfield (or backglass insert) is out.
GI string out on a game with under-playfield GI relays
Cause: Many System 7 games switch GI strings with 12 V DC relays under the playfield or on the insert board. The relay contacts are normally closed, so a dead string is usually a poor lug connection on the relay.
Checks
- Find the relay: five lugs, centre one unused. Two carry the GI wires (solid yellow or purple), two carry 12 V and the return to the driver board TIP122.
- Check the GI wire lugs for loose or corroded crimp connectors.
Fix
- Crimp on fresh lug terminals, or tighten the existing ones with pliers.
Systems
Related tips
- The solenoid L/R select relay and transistor Q29
- Kicker coil locks on again after a new TIP122: dead 7408 gate on the driver board
- F5 blows on a flip, then slings dead: shorted drivers and a loose coil power wire
- 50 V coils use PPB TIP36c transistors, pre-driven from the CPU board
- Multiplexed L/R (A/B) banks and wire colours
- Three-stage drive for 50 V coils
- Where the TIP122 drivers are on the CPU board
- How a coil or flasher is switched: PIA to TTL to pre-driver to driver
Source: Repairing Williams System 3 to System 7 Pinball 1977 to 1984, Part Two, Clay Harrell (pinrepair.com)