pintech.app

The +12 V switch matrix fuse blows immediately every time.

Switch matrix fuse F115 (F101 on WPC-95) blows as soon as it is replaced

Cause: A blown CPU board U20 (ULN2803A), sometimes with U14 (U23 on WPC-S/WPC-95); or a short in the playfield wiring or on an under-playfield opto board, such as solder splashes, a stray nut or bolt, or a lamp, flasher or coil lug touching a switch lug (above or below the playfield).

Checks

  • Game off, fit a new fuse and unplug J114 (J101 on WPC-95) from the driver board, then power on (ignore the complaints).
  • Fuse blows with J114/J101 unplugged: the CPU board is at fault, usually U20.
  • Fuse holds and the +12 V LED is lit: reconnect J114/J101, unplug the opto board power (the board has a red power LED), and power on. If the fuse now holds, the opto board is the culprit.
  • Otherwise look under and on top of the playfield for anything shorting a power circuit to the switch wiring.

Fix

  • Replace U20 in a socket (and U14/U23 if needed), repair the opto board, or clear the short.

Systems

Related tips

Source: Repairing Williams/Bally WPC Pinball Games from 1990 to 1999, Part Two, Clay Harrell (pinrepair.com)