A general illumination string stays dark, often after the driver board GI connector pins were replaced.
GI string dead after connector replacement: broken traces
Cause: Cracked plated-through holes or broken traces at the .156 inch GI header pins, so the pins no longer connect to the fuse holders or triacs. Failed triacs are very rare.
Checks
- Set the meter to continuity and check each GI header pin through to its fuse holder and triac, using the schematics for pin, fuse and triac numbers.
Fix
- Repair broken traces or holes with jumper wires.
Systems
Related tips
- GI string still dead after replacing J115: broken through-hole, add a jumper
- One GI string is out
- One GI string dead though the board and fuse test fine: burnt connector in the cabinet
- Several GI strings dead after a connector repair: lifted pads at J115
- Two GI strings still dead after fixing a burnt J120: broken pads and traces
- No GI at all
- General illumination strings
- One GI string dead after a restoration: unkeyed J115 plugged in upside down
Source: Repairing Williams/Bally WPC Pinball Games from 1990 to 1999, Part Three, Clay Harrell (pinrepair.com)