Checking GI triacs with the game on
Steps
- Put the game in the GI test with all strings at full (level 8).
- Meter on AC, black probe to ground.
- Probe the tab screw of each triac heat sink in turn: about 1 V AC or a little less means that triac is switching.
- Feel each heat sink; a cold one is not switching on. Usually the cause is the J115 input connector, the fuse or a broken trace, not the triac.
Systems
Related tips
- One GI string dead though the board and fuse test fine: burnt connector in the cabinet
- GI string still dead after replacing J115: broken through-hole, add a jumper
- One GI string dead after a restoration: unkeyed J115 plugged in upside down
- Several GI strings dead after a connector repair: lifted pads at J115
- All GI out (playfield and backbox) with good fuses and plugs: reseat the CPU ASIC and ROM
- All backbox lights out with good fuses: burned J120 GI connector
- A whole string of backbox lamps is out: blown GI fuse F110
- Two GI strings still dead after fixing a burnt J120: broken pads and traces
Source: Repairing Williams/Bally WPC Pinball Games from 1990 to 1999, Part Three, Clay Harrell (pinrepair.com)