The 5 V regulator section of the solenoid driver board makes 5 V with no load, but as soon as the 5 V is connected to the rest of the board (or the board is plugged in) all the low voltages sag to a volt or less.

Solenoid board 5 V collapses under load: open 12 V bridge on the rectifier board

Cause: The bridge rectifier that makes the 12 V on the rectifier board had an open section. It measured fine on a meter and showed 12 V unloaded, but could not supply any real current.

Checks

  • Load-test the 12 V DC at the rectifier board with a 12 V automotive bulb from the 12 V test point to ground: a good supply lights it brightly.
  • If the bulb lights on the transformer's 12 V AC winding but not on the 12 V DC, the bridge, its fuse, filter capacitor C23 or the wiring between them is at fault.
  • Running the solenoid board from a bench supply confirms whether the board itself is good.

Fix

  • Replace the original bridge rectifier for the 12 V on the rectifier board, even if it tests good with a meter.

Transformer AC is live on the rectifier board while you measure; keep fingers clear and power off before removing the board.