After the start-up test the display asks you to check fuses F114 and F115, and switch test shows switch 24 (the always-closed switch) open. The fuses test good.
'Check F114 and F115' with switch 24 open: missing 12 V, bad bridge BR5
Cause: The unregulated 12 V supply is missing. Here one diode in bridge rectifier BR5 on the power driver board had gone open.
Checks
- Measure the unregulated 12 V at test point TP1 on the driver board.
- If it is missing with good fuses, check that AC is reaching the board (it was present at J112), then test bridge BR5 and its filter capacitor.
Fix
- Replace the failed bridge rectifier (BR5 here). The 12 V returned and the game played normally.
AC from the transformer is live on the driver board connectors while you measure; keep probes steady and power off before removing the board.
Systems
Games
Related tips
- Shorted or open bridge rectifiers
- Driver board LED1 off (+12 V regulated missing)
- Live voltage checks for the F114/F115 message
- Pre-WPC-95 bridges, filter caps and fuses by supply
- Every opto dead and the opto board LED off: failed bridge BR5 for the unregulated 12 V
- Driver board LED1 off: switch matrix 12 V missing (WPC-S and earlier)
- No ball to the shooter lane and trap door or trunk dead: blown solenoid fuse
- Testing a bridge rectifier out of circuit