A lamp row stays dead or stuck after its row transistor and the matrix resistors have been checked.
Lamp row still dead after a new TIP122
Cause: The row drive chain: 7406 chips at 11F and 12E, the 2N5060 SCRs at Q81 to Q88, the diode on the CPU board for each row SCR, or the PIA at 11D.
Checks
- Diode-test the row diode on the CPU board.
- Test the 2N5060 for that row.
- Probe the 7406 outputs.
Fix
- Replace the failed diode, SCR, 7406 or PIA.
Systems
Related tips
- Lamp and switch matrix transistor positions on the CPU board
- CPU flipper enable relay RY1
- Lamp matrix still wrong after replacing transistors: upstream parts
- Lamp matrix row test at 2J7 with Leon's code
- Lamp rows stuck on: the 7406 at IC19
- Test a 2N5060 lamp matrix SCR with a meter
- Lamp matrix fault with good transistors: check R55 to R62
- Lamp driver SCRs on the CPU board
Source: Repairing DataEast 1987 (Laser War) to Sega 1995 (Batman Forever), Part Three, Clay Harrell (pinrepair.com)