pintech.app

Test a 2N5060 lamp matrix SCR with a meter

Steps

  • Meter on diode test.
  • Red lead on the middle leg.
  • Black lead on the right leg: expect about 0.5 to 0.7 V.
  • Black lead on the left leg: expect about 0.9 to 1.1 V.

Systems

Related tips

Source: Repairing Williams System 3 to System 7 Pinball 1977 to 1984, Part Two, Clay Harrell (pinrepair.com)