Why a 3 A fuse rather than Gottlieb's 5 A on kicker coils
Gottlieb bulletin 11-P0182 (January 1982) calls for a 5 A slow-blow fuse on these kicker coils. In the guide's test a locked-on coil took over 20 seconds to blow a 5 A fuse and had started to scorch, while a 3 A slow-blow went in about 3 seconds, which is still far longer than a kicker is ever meant to be on.
Systems
Related tips
- Gottlieb EL fuse numbers by rating
- Bottom board fuses and what each feeds
- Under-playfield fuses on System 80 games
- Test fuses out of the holder and never over-fuse
- Haunted House playfield fuses
- Black Hole playfield fuses
- Check the bottom board and playfield fuses early
- Primary line fuse rating
Source: Repairing & Upgrading Gottlieb System 80 Pinballs from 1980 to 1989, Part Two, Clay Harrell (pinrepair.com)