Totals or settings in bookkeeping steps 1 to 15 are wrong or blank. When a value in steps 1-10 or step 15 blinks, the game suspects it is corrupt.
Bookkeeping totals or score levels are wrong or missing
Cause: Lost or corrupted battery-backed memory, or a faulty control board.
Checks
- Go to the faulty step and clear it to zero with the credit button, then move on.
- Score levels (steps 11 to 14): clear, then hold the credit button until the wanted level appears before moving on. When these levels get lost, the game refills them with defaults stored in its PROM.
- Once corrected, cycle the power and look at the values again.
Fix
- If the data cannot be cleared or new levels cannot be set, the control board is faulty.
- If the values are lost again after a power cycle, the control board (memory back-up) is faulty.
Systems
Related tips
- Scores light at once and the status display stays dark
- Random game over, lost credits or erratic features
- Game check-out, part 2: what a healthy power-up looks like
- How the control board reset circuit works
- A playfield switch triggers the wrong response
- All displays are dark
- Checking lamp signals during test step 16
- Game check-out, part 3: walk through bookkeeping and self-test
Source: System 80 Service Manual, Gottlieb