pintech.app

Socketing a replacement spider chip

Steps

  • Desolder the failed spider.
  • Solder single-row machine-pin SIP sockets into the board.
  • Press a second layer of SIP strips onto the spider legs.
  • Plug the spider, with its extra strips, into the board sockets; the wide legs then wear the loose strips, not the soldered ones, and alignment is easier.

Systems

Related tips

Source: Gottlieb System 1 Pinball Repair from 1977 to 1980, Clay Harrell (pinrepair.com)