F5 on the playfield power (PPB) board blows, and a fuse in the backbox blows the instant the game is switched on.
Data East/Sega: PPB fuse and backbox fuse blowing: shorted Q3 and a plug one pin over
Cause: Two separate faults: the TIP36C transistor at Q3 on the PPB board had shorted, and a previous owner had plugged a power supply connector (CN4) on one pin offset, shorting the supply.
Checks
- Meter the transistors on the PPB board; a shorted one reads near zero.
- With power off, measure resistance across the blowing fuse and unplug the load connectors one at a time until the short disappears.
- Check every power supply connector is on its header squarely and not shifted by a pin; look for burnt connectors while there.
Fix
- Replace the shorted Q3 transistor on the PPB board.
- Refit the offset connector correctly and replace any burnt connectors.
Fuse hunting involves the transformer and supply; take resistance readings with the game unplugged.
Systems
Related tips
- PPB fuses on the nine-fuse board
- Dead or intermittent circuit from a cracked fuse clip
- MRB and PPB playfield power boards
- Under-playfield relay boards and the PPB board
- Only GI for 10-15 minutes after power-on, coils lock on and blow fuses: weak 5 V supply
- A coil or flasher comes on and stays on at power-up
- What the PPB/MRB board carries
- DMD shows random garbage after reassembly: failed display driver board
Source: Pinball Repair help group!! (Facebook group)