pintech.app

F5 on the playfield power (PPB) board blows, and a fuse in the backbox blows the instant the game is switched on.

Data East/Sega: PPB fuse and backbox fuse blowing: shorted Q3 and a plug one pin over

Cause: Two separate faults: the TIP36C transistor at Q3 on the PPB board had shorted, and a previous owner had plugged a power supply connector (CN4) on one pin offset, shorting the supply.

Checks

  • Meter the transistors on the PPB board; a shorted one reads near zero.
  • With power off, measure resistance across the blowing fuse and unplug the load connectors one at a time until the short disappears.
  • Check every power supply connector is on its header squarely and not shifted by a pin; look for burnt connectors while there.

Fix

  • Replace the shorted Q3 transistor on the PPB board.
  • Refit the offset connector correctly and replace any burnt connectors.

Fuse hunting involves the transformer and supply; take resistance readings with the game unplugged.

Systems

Related tips

Source: Pinball Repair help group!! (Facebook group)