Quick diode test of a bottom-panel bridge rectifier
Steps
- With power off, set the meter to diode test.
- Red lead on the ground lug (the one with the green wire); black lead on each of the two neighbouring lugs in turn: expect 0.4 to 0.6.
- Black lead on the positive lug (diagonal from ground; on newer bridges it is turned 90 degrees); red lead on each neighbouring lug in turn: expect 0.4 to 0.6.
- Any reading outside that range means the bridge is bad; replace it with a 35 A 400 V lug-type bridge.