First power-up, step 1: check the bottom-panel fuses
Steps
- With the game off, pull each bottom-panel fuse and test it out of the holder on continuity.
- Leave blown fuses out for now and note what each one feeds from its label.
- If the 6 V CPU lamp fuse is blown, test its bridge rectifier, since a shorted bridge blows its fuse.
- If the display fuse (about 60-69 V) is blown on 80/80A, suspect one of the four 1N4004 diodes on the power supply that rectify it.
- A blown 6.3 V GI fuse often means a shorted lamp socket on the playfield.
- On 80/80A, replace the orange 12 V logic filter capacitor while you are there.
- Finally, take the 28 V solenoid fuse out and set it aside before going on.
The bottom panel carries 120 V AC from the wall; unplug the game before touching the line filter, fuse block or transformers.