A fuse blows immediately at power-on, for example F4 on Black Hole or Haunted House.
A bottom-panel fuse blows the moment the game is switched on
Cause: The bridge rectifier feeding that fuse has shorted.
Checks
- Diode-test the bridge: black lead on +, red on each AC lug, expect 0.4 to 0.6; then red lead on -, black on each AC lug, expect 0.4 to 0.6.
Fix
- Replace the bridge with an MB3502 or MB3504 lug bridge (35 A, 200 or 400 V); a higher rating is fine but never lower.
The bottom panel carries 120 V AC from the wall; unplug the game before touching the line filter, fuse block or transformers.
Systems
Related tips
- First power-up, step 1: check the bottom-panel fuses
- Bottom-panel bridge rectifiers and fuses
- Replacement bridge rectifiers
- Haunted House and Black Hole fuse panel
- Quick diode test of a bottom-panel bridge rectifier
- Check the 80B bottom-cabinet 10,000 mfd filter capacitor
- System 80B ground lost at the transformer panel plugs
- Haunted House playfield fuses
Source: Repairing & Upgrading Gottlieb System 80 Pinballs from 1980 to 1989, Part One, Clay Harrell (pinrepair.com)